Monitoring Welding

Quality and reliability of welds are crucial elements for the successful completion of a project. LOGIC supports its clients in fully mastering the welding process—from defining procedures to final quality control, including welder qualification and production follow-up.

Welding book writting
  • Drafting of WPS tailored to the project’s needs.

  • Preparation, review, and approval of welding procedure documentation, in compliance with company qualifications and contractual requirements.

  • Technical selection of welding processes according to project requirements and available equipment.

  • Supervision and implementation of Procedure Qualification Records (PQR) and Welder Qualification Tests (WQT) through accredited bodies.

  • Coordination with experienced welders selected by LOGIC to ensure a high level of expertise.

  • Drafting and reviewing technical welding procedures in accordance with client requirements.

  • Management and verification of the weld/pipe book to ensure complete traceability.

  • Creation of self-inspection records and technical reports (welding parameters, gouging, visual inspection, etc.).

  • Monitoring, renewal, and follow-up of welder qualifications.

  • Inspection and monitoring of welding equipment during production.

  • Analysis and verification of compliance with client requirements: codes, standards, specifications, and validated procedures.

  • Monitoring of welding parameters in line with WPS implementation.

  • Organization of welding teams according to production needs and available skills/qualifications.

  • Management of welding consumables supply and verification of 3.1 material certificates.

  • Coordination of NDT in line with daily production schedules.

  • Verification of NDT reports by qualified personnel.

  • Independent reassessments in case of dispute, performed by experienced inspectors.

  • Supervision of various NDT methods, including: Visual Testing (VT), Dye Penetrant Testing (PT), Magnetic Particle Testing (MT), Radiographic Testing (RT), and Ultrasonic Testing (UT).